About Us


Services


Careers


Trade Shows


News & Articles

eNews

Industry News and Updates

Product News


Contact Us


KTA-TATOR, INC.
Corporate Headquarters
115 Technology Drive
Pittsburgh, PA 15275
Phone: 412.788.1300
Fax: 412.788.1306
E-mail:
info@kta.com

Instrument Sales
1-800-KTA-GAGE

Lead Hotline
1-800-LEAD-OFF


Home

Product News

NEW - Nuclear Coatings Inspection Kits

Basic Nuclear Coatings Inspection Kit includes:KTA Basic Nuclear Inspection Kit

  • Sling Psychrometer
  • PTC Surface Temperature Thermometer
  • US Weather Bureau Psychrometric Tables
  • Blotter Paper
  • SSPC Surface Preparation Specifications
  • Testex X-Course Press-O-Film Tape
  • Testex Micrometer
  • Inspection Mirror
  • Paint Thermometer
  • Wet Film Thickness Gage
  • Positector 6000 F1 with Plastic Shims
  • SSPC-PA2 (Substitute NIST Calibration Standards for $750, when purchased with a kit)
  • Hard Shell Carrying Case

Advanced Nuclear Coatings Inspection Kit includes:
*Shown with optional NIST Calibration Standards
KTA Advanced Nuclear Inspection Kit

  • DeFelsko Dew Meter
  • Blotter Paper
  • SSPC Surface Preparation Specifications
  • Testex X-Course Press-O-Film Tape
  • Testex Micrometer
  • Inspection Mirror
  • Paint Thermometer
  • Wet Film Thickness Gage
  • Positector 6000 F2 with Plastic Shims
  • SSPC-PA2 (Substitute NIST Calibration Standards for $750, when purchased with a kit)
  • Hard Shell Carrying Case

Additional Instrumentation Recommendations

  • Certificates of Calibration Through an A2LA or NAVLAP Certified Laboratory
  • pH Colorfast Strips
  • SSPC-VIS 1, Abrasive Blast Cleaning Visual Standards
  • SSPC-VIS 3, Hand/Power Tool Cleaning Visual Standards
  • Ferrous/Non Ferrous DFT Gage (Elcometer, DeFelsko, Electrophysik, Fisher, Testcoat)
  • DFT Gage with Memory and Downloading (Elcometer, DeFelsko, Electrophysik, Fisher, Testcoat)
  • Positector 200 (measaurement of coatings on concrete)
  • Tooke Gage
  • Elecometer Model 106 Adhesion Tester
  • Instructional Book, “Using Coatings Inspection Instruments”

Basic Nuclear Inspection Kit: $1,098.00
Advanced Nuclear Inspection Kit: $1,795.00

To order thess or any inspection instrument, please call the KTA Instrument Sales Department at 1.800.KTA.GAGE.

Visit www.ktagage.com for all of your inspection instrument needs.

StarCertificates of Calibration are available for many of the instruments.


Using Coatings Inspection Instruments 2nd Edition, by W.D.Corbett

The first comprehensive publication on the proper use of over 40 coatings inspection instruments, visual guides and surface contamination analysis test kits is now available from KTA-Tator, Inc., the industry leader in inspection sales and service. The fully illistrated (over 350 full color images), 300 page handbook contains eleven modules, each with workshops describing the step-by-step use of instruments, visual standards and test kits for:

  • Measuring Ambient Conditions and Surface Temperature
  • Measuring Surface Profile Depth
  • Assessing Surface Cleanliness UsingVisual Standards
  • Assessing Surface Cleanliness - Soluble Salt Contamination
  • Calculating and Measuring Wet Film Thickness
  • Measuring Coating Thickness Nondestructively on Ferrous and Non-Ferrous Metal Surfaces
  • Using Instruments for Inspecting Concrete Coatings
  • Measuring Coating Thickness Using the Tooke Gage
  • Measuring the Adhesion of Coatings
  • Detecting Pinholes and Holidays in Coatings and Linings
  • Detecting Amine Exudate (Blush) on Polyamide and Polyamine-cured Epoxy Coatings by Elevated Surface Alkalinity

The handbook also includes instructions for administering each of the module workshops, and includes a glossary of terms and an index of industry standards.

Order Book


Compliance Programs

KTA's team of Certified Industrial Hygienists, Coatings Consultants, Safety Professionals, and Environmental Engineers have designed compliance programs to help industrial facilty owners and commercial painting/decorating contractors comply with OSHA and EPA requirements as well as SSPC PCCP QP-1 and QP-2 requirements. All programs are easily tailored to address site-specific conditions. Available programs include:

  • Corporate Worker Safety and Health Program
    • Addresses OSHA 29 CFR 1926 regulations relative to industrial painting. Also meets the safety program requirements for QP-1 & QP-2.
  • Corporate Worker Safety and Health Program 1910
    • Addresses OSHA 29 CFR 1910 regulations relatvie to petrochemical refineries. 29 CFR 1910 focuses on work performed in industrial facilities.
  • Corporate Deleading Compliance Program
    • Designed to help owners/contractors comply with OSHA, EPA, and QP-2 requirements regarding the safe and proper removal, containment and disposal of hazardous (lead) paint.
  • Corporate Respiratory Protection Program
  • Corporate Worker Lead Protection Program
    • Addresses OSHA 29 CFR 1926 regulations relative to industrial painting. Also meets the safety program requirements for QP-1 & QP-2. This program includes the updated respiratory protection requirements.
    • Individual supplements on silica, cadmium, etc. are available.
  • Quality Control Program
    • Designed to establish management, technical, and inspection capabilities regarding the removal and application of coatings in compliance with QP-1 requirements

For more information on KTA's Compliance Programs visit KTA's Services on this web site. Please contact Dan O'Malley at 412.788.1300, extension 138, or e-mail at domalley@kta.com to set-up a training class for your employees.

To keep informed and to have the KTA eNews delivered directly to your IN box with great articles and news from KTA and the industry, please send your e-mail address to us.

 

© 2004 KTA-Tator, Inc. All Rights Reserved. Privacy Statement
Site maintained by KTA. webmaster@kta.com
Best viewed with Microsoft Internet Explorer